Sign In Register

Coolin, ID

Full City Profile · Idaho · Bonner County County

3.0 /5.0
B Good
24 Population 47/sq mi density
45°F Avg Temperature 248 sunny days/yr
175 Violent Crime/100K 2,334 property/100K
B
Overall
3.0 / 5.0
Good overall score based on economy, affordability, safety and education
F
Safety
1.0 / 5.0
175 violent crimes/100K
A+
Education
5.0 / 5.0
0.0% bachelor's degree or higher

Bridges in Coolin (43)

Concrete · Arch (Deck)
State Highway
Fair Built 1937 Rebuilt 1985 296 ft 2,600 vehicles/day
Deck: 5 · Super: 5 · Sub: 6
Steel · Culvert
County Highway
Good Built 2017 25 ft 1,800 vehicles/day
Steel continuous · Stringer/Multi-beam
County Highway
Fair Built 1951 225 ft 1,700 vehicles/day
Deck: 5 · Super: 5 · Sub: 6
Concrete · Stringer/Multi-beam
County Highway
Good Built 1996 67 ft 890 vehicles/day
Deck: 7 · Super: 7 · Sub: 7
Prestressed concrete · Box Beam (Multiple)
State Highway
Good Built 2020 46 ft 840 vehicles/day
Deck: 8 · Super: 8 · Sub: 8
Prestressed concrete · Tee Beam
County Highway
Poor Built 1975 Rebuilt 1994 24 ft 410 vehicles/day
Deck: 6 · Super: 6 · Sub: 3
Prestressed concrete · Stringer/Multi-beam
County Highway
Good Built 2018 63 ft 260 vehicles/day
Deck: 8 · Super: 8 · Sub: 8
Prestressed concrete · Tee Beam
County Highway
Fair Built 1972 62 ft 260 vehicles/day
Deck: 6 · Super: 6 · Sub: 7
Prestressed concrete · Tee Beam
County Highway
Fair Built 1970 40 ft 110 vehicles/day
Deck: 5 · Super: 5 · Sub: 7
Prestressed concrete · Tee Beam
County Highway
Fair Built 1970 Rebuilt 2015 42 ft 110 vehicles/day
Deck: 7 · Super: 6 · Sub: 6
Wood or Timber · Stringer/Multi-beam
US Forest Service
Fair Built 1954 29 ft 50 vehicles/day
Deck: 7 · Super: 8 · Sub: 6
Wood or Timber · Stringer/Multi-beam
US Forest Service
Poor Built 1956 29 ft 50 vehicles/day
Deck: 6 · Super: 6 · Sub: 3
Wood or Timber · Stringer/Multi-beam
US Forest Service
Fair Built 1952 35 ft 50 vehicles/day
Deck: 6 · Super: 7 · Sub: 6
Wood or Timber · Stringer/Multi-beam
US Forest Service
Poor Built 1954 29 ft 50 vehicles/day
Deck: 7 · Super: 7 · Sub: 4
Prestressed concrete · Tee Beam
US Forest Service
Good Built 2016 82 ft 50 vehicles/day
Deck: 8 · Super: 8 · Sub: 8
Wood or Timber · Stringer/Multi-beam
US Forest Service
Good Built 1986 29 ft 50 vehicles/day
Deck: 8 · Super: 8 · Sub: 7
Wood or Timber · Stringer/Multi-beam
US Forest Service
Fair Built 1964 36 ft 50 vehicles/day
Deck: 7 · Super: 8 · Sub: 6
Wood or Timber · Stringer/Multi-beam
US Forest Service
Poor Built 1955 29 ft 50 vehicles/day
Deck: 6 · Super: 7 · Sub: 4
Concrete continuous · Tee Beam
US Forest Service
Good Built 1952 Rebuilt 1998 110 ft 50 vehicles/day
Deck: 7 · Super: 7 · Sub: 7
Wood or Timber · Stringer/Multi-beam
US Forest Service
Fair Built 1954 33 ft 50 vehicles/day
Deck: 6 · Super: 7 · Sub: 5
Wood or Timber · Slab
US Forest Service
Fair Built 1989 29 ft 50 vehicles/day
Deck: 8 · Super: 8 · Sub: 6
Prestressed concrete · Stringer/Multi-beam
US Forest Service
Good Built 1990 40 ft 50 vehicles/day
Deck: 7 · Super: 7 · Sub: 7
Wood or Timber · Stringer/Multi-beam
US Forest Service
Poor Built 1972 40 ft 50 vehicles/day
Deck: 5 · Super: 6 · Sub: 4
Wood or Timber · Stringer/Multi-beam
US Forest Service
Fair Built 1974 42 ft 50 vehicles/day
Deck: 6 · Super: 6 · Sub: 6
Prestressed concrete continuous · Tee Beam
US Forest Service
Good Built 2010 116 ft 50 vehicles/day
Deck: 8 · Super: 8 · Sub: 8
Wood or Timber · Stringer/Multi-beam
US Forest Service
Poor Built 1953 33 ft 50 vehicles/day
Deck: 5 · Super: 7 · Sub: 3
Wood or Timber · Stringer/Multi-beam
US Forest Service
Fair Built 1964 25 ft 50 vehicles/day
Deck: 7 · Super: 7 · Sub: 6
Wood or Timber · Stringer/Multi-beam
US Forest Service
Poor Built 1953 27 ft 50 vehicles/day
Deck: 8 · Super: 7 · Sub: 2
Wood or Timber · Other
US Forest Service
Fair Built 1987 31 ft 50 vehicles/day
Deck: 6 · Super: 6 · Sub: 6
Wood or Timber · Stringer/Multi-beam
US Forest Service
Fair Built 1973 29 ft 50 vehicles/day
Deck: 7 · Super: 7 · Sub: 5
Prestressed concrete · Stringer/Multi-beam
US Forest Service
Fair Built 1988 82 ft 50 vehicles/day
Deck: 6 · Super: 6 · Sub: 7
Wood or Timber · Stringer/Multi-beam
US Forest Service
Fair Built 1964 29 ft 40 vehicles/day
Deck: 6 · Super: 8 · Sub: 7
Wood or Timber · Stringer/Multi-beam
US Forest Service
Good Built 1952 33 ft 40 vehicles/day
Deck: 7 · Super: 7 · Sub: 7
Concrete · Tee Beam
County Highway
Fair Built 1975 38 ft 40 vehicles/day
Deck: 6 · Super: 6 · Sub: 5
Wood or Timber · Stringer/Multi-beam
US Forest Service
Fair Built 1979 29 ft 40 vehicles/day
Deck: 7 · Super: 7 · Sub: 6
Prestressed concrete continuous · Stringer/Multi-beam
US Forest Service
Good Built 2010 82 ft 40 vehicles/day
Deck: 8 · Super: 8 · Sub: 8
Prestressed concrete continuous · Stringer/Multi-beam
US Forest Service
Good Built 2010 63 ft 40 vehicles/day
Deck: 8 · Super: 8 · Sub: 8
Prestressed concrete continuous · Stringer/Multi-beam
US Forest Service
Good Built 2007 61 ft 40 vehicles/day
Deck: 8 · Super: 8 · Sub: 8
Wood or Timber · Stringer/Multi-beam
US Forest Service
Fair Built 1952 33 ft 40 vehicles/day
Deck: 6 · Super: 7 · Sub: 6
Steel continuous · Stringer/Multi-beam
US Forest Service
Fair Built 1965 Rebuilt 1998 90 ft 40 vehicles/day
Deck: 7 · Super: 6 · Sub: 7
Steel continuous · Stringer/Multi-beam
US Forest Service
Fair Built 1965 Rebuilt 1998 90 ft 40 vehicles/day
Deck: 7 · Super: 6 · Sub: 7
Steel · Truss (Thru)
County Highway
Poor Built 1939 122 ft 30 vehicles/day
Deck: 6 · Super: 4 · Sub: 3
Concrete · Tee Beam
US Army
Fair Built 1974 24 ft 20 vehicles/day
Deck: 6 · Super: 6 · Sub: 5