Sign In Register

Princeton, ID

Full City Profile · Idaho · Latah County County

3.0 /5.0
B Good
29 Population 45/sq mi density
47°F Avg Temperature 276 sunny days/yr
49 Violent Crime/100K 2,846 property/100K
B
Overall
3.0 / 5.0
Good overall score based on economy, affordability, safety and education
F
Safety
1.0 / 5.0
49 violent crimes/100K
A+
Education
5.0 / 5.0
0.0% bachelor's degree or higher

Bridges in Princeton (18)

Concrete continuous · Tee Beam
State Highway
Fair Built 1953 113 ft 920 vehicles/day
Deck: 6 · Super: 5 · Sub: 6
Concrete · Frame
State Highway
Fair Built 1959 23 ft 920 vehicles/day
Deck: 7 · Super: 7 · Sub: 6
Steel · Stringer/Multi-beam
Army Corps of Engineers
Fair Built 1974 80 ft 870 vehicles/day
Deck: 7 · Super: 7 · Sub: 5
Prestressed concrete · Box Beam (Multiple)
State Highway
Fair Built 1974 81 ft 710 vehicles/day
Deck: 6 · Super: 6 · Sub: 7
Prestressed concrete · Stringer/Multi-beam
State Highway
Fair Built 1991 79 ft 710 vehicles/day
Deck: 6 · Super: 8 · Sub: 8
Steel · Culvert
State Highway
Good Built 1991 21 ft 710 vehicles/day
Steel · Stringer/Multi-beam
Army Corps of Engineers
Fair Built 1970 32 ft 30 vehicles/day
Deck: 6 · Super: 5 · Sub: 6
Steel · Stringer/Multi-beam
Army Corps of Engineers
Fair Built 1970 30 ft 30 vehicles/day
Deck: 6 · Super: 6 · Sub: 5
Steel · Stringer/Multi-beam
Army Corps of Engineers
Fair Built 1970 30 ft 30 vehicles/day
Deck: 6 · Super: 6 · Sub: 5
Steel · Stringer/Multi-beam
Army Corps of Engineers
Fair Built 1965 Rebuilt 2015 26 ft 30 vehicles/day
Deck: 7 · Super: 5 · Sub: 5
Steel · Stringer/Multi-beam
Army Corps of Engineers
Fair Built 1982 28 ft 30 vehicles/day
Deck: 5 · Super: 6 · Sub: 5
Steel · Stringer/Multi-beam
Army Corps of Engineers
Fair Built 1970 24 ft 30 vehicles/day
Deck: 5 · Super: 5 · Sub: 5
Prestressed concrete · Tee Beam
Army Corps of Engineers
Good Built 1993 30 ft 30 vehicles/day
Deck: 8 · Super: 8 · Sub: 7
Steel · Stringer/Multi-beam
Army Corps of Engineers
Fair Built 1975 36 ft 30 vehicles/day
Deck: 6 · Super: 6 · Sub: 6
Steel · Stringer/Multi-beam
Army Corps of Engineers
Fair Built 1980 80 ft 30 vehicles/day
Deck: 6 · Super: 6 · Sub: 5
Steel · Stringer/Multi-beam
Army Corps of Engineers
Fair Built 1984 28 ft 30 vehicles/day
Deck: 6 · Super: 7 · Sub: 6
Prestressed concrete · Tee Beam
Army Corps of Engineers
Fair Built 1991 45 ft 30 vehicles/day
Deck: 7 · Super: 7 · Sub: 6
Steel · Stringer/Multi-beam
Army Corps of Engineers
Fair Built 1970 31 ft 20 vehicles/day
Deck: 6 · Super: 6 · Sub: 6