Sign In Register

Stanley, ID

Full City Profile · Idaho · Custer County County

3.0 /5.0
B Good
281 Population 520/sq mi density
34°F Avg Temperature 311 sunny days/yr
222 Violent Crime/100K 2,255 property/100K
B
Overall
3.0 / 5.0
Good overall score based on economy, affordability, safety and education
F
Safety
1.0 / 5.0
222 violent crimes/100K
A+
Education
5.0 / 5.0
80.4% bachelor's degree or higher

Bridges in Stanley (76)

Concrete · Culvert
State Highway
Fair Built 1968 21 ft 1,800 vehicles/day
Concrete continuous · Tee Beam
State Highway
Fair Built 1960 130 ft 1,100 vehicles/day
Deck: 6 · Super: 6 · Sub: 6
Prestressed concrete · Stringer/Multi-beam
State Highway
Fair Built 1977 45 ft 970 vehicles/day
Deck: 6 · Super: 7 · Sub: 6
Prestressed concrete · Tee Beam
State Highway
Fair Built 1974 26 ft 970 vehicles/day
Deck: 6 · Super: 6 · Sub: 6
Prestressed concrete · Stringer/Multi-beam
State Highway
Fair Built 1977 33 ft 750 vehicles/day
Deck: 6 · Super: 7 · Sub: 6
Prestressed concrete · Tee Beam
State Highway
Fair Built 1974 28 ft 750 vehicles/day
Deck: 5 · Super: 5 · Sub: 6
Prestressed concrete · Stringer/Multi-beam
State Highway
Good Built 1985 103 ft 750 vehicles/day
Deck: 7 · Super: 7 · Sub: 7
Prestressed concrete · Tee Beam
State Highway
Fair Built 1974 26 ft 750 vehicles/day
Deck: 6 · Super: 6 · Sub: 6
Prestressed concrete · Tee Beam
State Highway
Fair Built 1974 26 ft 750 vehicles/day
Deck: 7 · Super: 6 · Sub: 7
Prestressed concrete continuous · Stringer/Multi-beam
State Highway
Fair Built 1985 154 ft 750 vehicles/day
Deck: 6 · Super: 8 · Sub: 5
Concrete continuous · Tee Beam
State Highway
Poor Built 1934 200 ft 660 vehicles/day
Deck: 4 · Super: 4 · Sub: 5
Prestressed concrete · Box Beam (Multiple)
State Highway
Fair Built 2007 51 ft 660 vehicles/day
Deck: 6 · Super: 6 · Sub: 7
Prestressed concrete · Box Beam (Multiple)
State Highway
Fair Built 1977 111 ft 660 vehicles/day
Deck: 5 · Super: 5 · Sub: 6
Concrete · Frame
State Highway
Good Built 2022 28 ft 560 vehicles/day
Deck: 8 · Super: 8 · Sub: 9
Concrete · Tee Beam
State Highway
Fair Built 1964 90 ft 560 vehicles/day
Deck: 6 · Super: 6 · Sub: 6
Concrete continuous · Tee Beam
State Highway
Fair Built 1966 90 ft 560 vehicles/day
Deck: 6 · Super: 6 · Sub: 6
Prestressed concrete · Box Beam (Multiple)
State Highway
Fair Built 1964 110 ft 560 vehicles/day
Deck: 6 · Super: 6 · Sub: 6
Concrete · Tee Beam
State Highway
Fair Built 1964 115 ft 560 vehicles/day
Deck: 6 · Super: 7 · Sub: 7
Concrete continuous · Tee Beam
State Highway
Good Built 1964 120 ft 560 vehicles/day
Deck: 7 · Super: 7 · Sub: 7
Steel · Stringer/Multi-beam
US Forest Service
Good Built 2015 110 ft 500 vehicles/day
Deck: 7 · Super: 8 · Sub: 8
Steel · Stringer/Multi-beam
County Highway
Fair Built 1966 106 ft 200 vehicles/day
Deck: 6 · Super: 7 · Sub: 7
Wood or Timber · Stringer/Multi-beam
US Forest Service
Fair Built 1961 Rebuilt 2004 36 ft 100 vehicles/day
Deck: 7 · Super: 8 · Sub: 6
Prestressed concrete · Girder/Floorbeam
US Forest Service
Fair Built 1972 Rebuilt 2000 34 ft 100 vehicles/day
Deck: 6 · Super: 8 · Sub: 7
Prestressed concrete · Girder/Floorbeam
US Forest Service
Good Built 1972 Rebuilt 2000 102 ft 100 vehicles/day
Deck: 7 · Super: 8 · Sub: 7
Wood or Timber · Stringer/Multi-beam
US Forest Service
Poor Built 1957 Rebuilt 1999 26 ft 100 vehicles/day
Deck: 4 · Super: 7 · Sub: 4
Prestressed concrete continuous · Box Beam (Multiple)
US Forest Service
Poor Built 1993 Rebuilt 1999 32 ft 100 vehicles/day
Deck: 3 · Super: 3 · Sub: 6
Wood or Timber · Slab
US Forest Service
Fair Built 2001 28 ft 100 vehicles/day
Deck: 6 · Super: 6 · Sub: 7
Wood or Timber · Stringer/Multi-beam
US Forest Service
Fair Built 1964 90 ft 100 vehicles/day
Deck: 6 · Super: 6 · Sub: 6
Wood or Timber · Slab
US Forest Service
Good Built 1992 24 ft 100 vehicles/day
Deck: 7 · Super: 7 · Sub: 7
Wood or Timber · Stringer/Multi-beam
US Forest Service
Good Built 1969 22 ft 80 vehicles/day
Deck: 7 · Super: 7 · Sub: 7
Prestressed concrete · Stringer/Multi-beam
US Forest Service
Good Built 1972 86 ft 80 vehicles/day
Deck: 7 · Super: 8 · Sub: 7
Prestressed concrete · Slab
US Forest Service
Good Built 1986 40 ft 60 vehicles/day
Deck: 8 · Super: 8 · Sub: 7
Wood or Timber · Stringer/Multi-beam
US Forest Service
Fair Built 1982 32 ft 50 vehicles/day
Deck: 7 · Super: 6 · Sub: 7
Wood or Timber · Slab
County Highway
Fair Built 1974 24 ft 50 vehicles/day
Deck: 7 · Super: 7 · Sub: 6
Prestressed concrete · Girder/Floorbeam
US Forest Service
Poor Built 1972 Rebuilt 2000 87 ft 50 vehicles/day
Deck: 6 · Super: 7 · Sub: 4
Prestressed concrete · Slab
US Forest Service
Good Built 2012 36 ft 50 vehicles/day
Deck: 8 · Super: 8 · Sub: 8
Steel · Girder/Floorbeam
US Forest Service
Fair Built 1953 Rebuilt 1999 74 ft 50 vehicles/day
Deck: 7 · Super: 6 · Sub: 6
Wood or Timber · Tee Beam
US Forest Service
Good Built 2013 28 ft 50 vehicles/day
Deck: 7 · Super: 7 · Sub: 7
Wood or Timber · Stringer/Multi-beam
US Forest Service
Poor Built 1950 68 ft 50 vehicles/day
Deck: 5 · Super: 5 · Sub: 3
Wood or Timber · Slab
US Forest Service
Fair Built 1957 24 ft 50 vehicles/day
Deck: 6 · Super: 6 · Sub: 8
Wood or Timber · Stringer/Multi-beam
US Forest Service
Fair Built 1969 157 ft 50 vehicles/day
Deck: 7 · Super: 6 · Sub: 7
Wood or Timber · Stringer/Multi-beam
US Forest Service
Fair Built 1955 34 ft 50 vehicles/day
Deck: 6 · Super: 6 · Sub: 6
Steel continuous · Stringer/Multi-beam
US Forest Service
Fair Built 1967 120 ft 50 vehicles/day
Deck: 7 · Super: 6 · Sub: 7
Wood or Timber · Stringer/Multi-beam
US Forest Service
Fair Built 1960 88 ft 50 vehicles/day
Deck: 6 · Super: 6 · Sub: 5
Wood or Timber · Stringer/Multi-beam
US Forest Service
Good Built 1984 24 ft 50 vehicles/day
Deck: 7 · Super: 7 · Sub: 7
Wood or Timber · Stringer/Multi-beam
US Forest Service
Good Built 1975 24 ft 50 vehicles/day
Deck: 7 · Super: 7 · Sub: 7
Prestressed concrete · Girder/Floorbeam
US Forest Service
Fair Built 1972 Rebuilt 2000 113 ft 50 vehicles/day
Deck: 6 · Super: 7 · Sub: 7
Wood or Timber · Stringer/Multi-beam
US Forest Service
Fair Built 1956 26 ft 50 vehicles/day
Deck: 6 · Super: 6 · Sub: 6
Steel · Stringer/Multi-beam
US Forest Service
Fair Built 1984 32 ft 50 vehicles/day
Deck: 8 · Super: 8 · Sub: 5
Wood or Timber · Slab
US Forest Service
Fair Built 1955 30 ft 50 vehicles/day
Deck: 6 · Super: 6 · Sub: 5
Wood or Timber · Stringer/Multi-beam
US Forest Service
Fair Built 1969 34 ft 50 vehicles/day
Deck: 7 · Super: 6 · Sub: 6
Prestressed concrete · Girder/Floorbeam
US Forest Service
Fair Built 1972 Rebuilt 2000 65 ft 50 vehicles/day
Deck: 6 · Super: 8 · Sub: 7
Prestressed concrete · Slab
US Forest Service
Good Built 2009 46 ft 50 vehicles/day
Deck: 8 · Super: 8 · Sub: 8
Prestressed concrete · Stringer/Multi-beam
US Forest Service
Good Built 1981 116 ft 50 vehicles/day
Deck: 8 · Super: 8 · Sub: 7
Steel · Girder/Floorbeam
US Forest Service
Fair Built 1964 Rebuilt 1999 51 ft 50 vehicles/day
Deck: 7 · Super: 6 · Sub: 6
Prestressed concrete · Girder/Floorbeam
US Forest Service
Fair Built 1972 Rebuilt 2000 105 ft 50 vehicles/day
Deck: 6 · Super: 8 · Sub: 7
Wood or Timber · Stringer/Multi-beam
US Forest Service
Fair Built 1979 Rebuilt 1999 24 ft 40 vehicles/day
Deck: 7 · Super: 7 · Sub: 6
Steel · Truss (Deck)
Army Corps of Engineers
Fair Built 1991 137 ft 30 vehicles/day
Deck: 6 · Super: 6 · Sub: 8
Steel continuous · Stringer/Multi-beam
Army Corps of Engineers
Fair Built 1965 79 ft 30 vehicles/day
Deck: 7 · Super: 6 · Sub: 7
Steel · Stringer/Multi-beam
Army Corps of Engineers
Fair Built 1958 51 ft 30 vehicles/day
Deck: 5 · Super: 6 · Sub: 6
Steel · Stringer/Multi-beam
US Army
Fair Built 1950 51 ft 30 vehicles/day
Deck: 6 · Super: 5 · Sub: 6
Steel · Truss (Thru)
Army Corps of Engineers
Poor Built 1962 63 ft 30 vehicles/day
Deck: 6 · Super: 6 · Sub: 4
Wood or Timber · Stringer/Multi-beam
US Forest Service
Fair Built 1979 34 ft 25 vehicles/day
Deck: 5 · Super: 6 · Sub: 7
Prestressed concrete · Stringer/Multi-beam
US Forest Service
Good Built 1976 83 ft 25 vehicles/day
Deck: 7 · Super: 8 · Sub: 7
Wood or Timber · Stringer/Multi-beam
US Forest Service
Fair Built 1965 36 ft 15 vehicles/day
Deck: 7 · Super: 6 · Sub: 6
Wood or Timber · Stringer/Multi-beam
US Forest Service
Fair Built 1976 30 ft 15 vehicles/day
Deck: 7 · Super: 7 · Sub: 6
Wood or Timber · Stringer/Multi-beam
US Forest Service
Fair Built 1967 Rebuilt 1999 27 ft 10 vehicles/day
Deck: 7 · Super: 6 · Sub: 7
Wood or Timber · Stringer/Multi-beam
US Forest Service
Fair Built 1968 Rebuilt 1999 27 ft 10 vehicles/day
Deck: 7 · Super: 7 · Sub: 6
Wood or Timber · Stringer/Multi-beam
US Forest Service
Fair Built 1968 Rebuilt 1999 33 ft 10 vehicles/day
Deck: 6 · Super: 7 · Sub: 7
Wood or Timber · Stringer/Multi-beam
US Forest Service
Fair Built 1964 Rebuilt 2000 31 ft 10 vehicles/day
Deck: 5 · Super: 6 · Sub: 6
Wood or Timber · Stringer/Multi-beam
US Forest Service
Fair Built 1967 Rebuilt 1999 22 ft 10 vehicles/day
Deck: 5 · Super: 7 · Sub: 5
Wood or Timber · Stringer/Multi-beam
US Forest Service
Fair Built 1967 Rebuilt 1999 31 ft 10 vehicles/day
Deck: 6 · Super: 6 · Sub: 6
Wood or Timber · Stringer/Multi-beam
US Forest Service
Fair Built 1957 Rebuilt 1999 31 ft 10 vehicles/day
Deck: 6 · Super: 7 · Sub: 6
Wood or Timber · Stringer/Multi-beam
US Forest Service
Fair Built 1967 Rebuilt 1999 31 ft 10 vehicles/day
Deck: 6 · Super: 7 · Sub: 7
Wood or Timber · Stringer/Multi-beam
US Forest Service
Fair Built 1968 Rebuilt 1999 27 ft 10 vehicles/day
Deck: 5 · Super: 7 · Sub: 6
Wood or Timber · Stringer/Multi-beam
US Forest Service
Fair Built 1972 Rebuilt 1999 25 ft 5 vehicles/day
Deck: 7 · Super: 7 · Sub: 6